Kochlin SPECIAL ALLOYS · SINCE 2009

Ti-2Al-1.5Mn

ГОСТ≈ ОТ4-1

Lean-alloyed sheet for press forming

Titanium
Units
Tensile Rm
590
MPa · ≥ std. min
Yield Rp0.2
460
MPa · ≥ std. min
Elongation A
25
% · ≥ std. min
Service limit
350
°C · indicative max
Density
4.55
g/cm³

Chemical composition

Ti 96%Al 1.8%Mn 1.4%Minor & residual 0.61%

Nominal: mid-range where both limits are given, the cap where only a maximum is, balance takes the remainder. Exact specified ranges below.

ElementName Content %
Main elements3 elements
Ti TitaniumBal.
Al Aluminium1 – 2.5%
Mn Manganese0.7 – 2%
ElementName Content %
Minor & residual5 elements
Fe Iron≤ 0.3%
O Oxygen≤ 0.15%
C Carbon≤ 0.1%
N Nitrogen≤ 0.05%
H Hydrogen≤ 0.012%

Mechanical minima by form

Guaranteed values differ by form, size and delivery condition; quotations confirm the specification, form, size and condition.

FormCondition Rm MPaRp0.2 MPaA ≥ %
PlateM, t 0.3–2.0 mm (Annealed) 590 – 735 ≥ 460 ≥ 25
PlateM, t >2.0–10.0 mm (Annealed) 590 – 735 ≥ 460 ≥ 20
PlateM, t >10.0–25.0 mm (Annealed) 590 – 735 ≥ 460 ≥ 15

Where this grade is recommended

Matched in 1 service conditions; ranks and scores computed from the condition-scoring matrix.

Service conditionIndustry TemperatureRankScore
Airframe & lightweight Aerospace ≤ 200 °C 10 / 10 74

Designations & equivalents

Trade name(s)Ti-2Al-1.5Mn
GOST (Russia)≈ ОТ4-1

Cross-references are common near-equivalents for search and shortlisting; substitution across standards requires clause-by-clause verification. All grades in one cross-reference table →

Applicable standards

2 specifications. Name the standard and its edition on the order.

Guaranteed values and required tests differ between specifications — see Mechanical minima by form for the figures per form.

Frequently asked questions

What is TC1 (Ti-2Al-1.5Mn)?

TC1 (Ti-2Al-1.5Mn) — Titanium. Lean-alloyed sheet for press forming

What is the maximum service temperature of TC1?

Typically about 350 °C; the practical limit depends on media, stress and design life — acceptance per the governing standard.

What is the tensile strength of TC1?

The specified minimum tensile strength is 590 MPa for the main product form. Minima for other forms and sizes are listed under "Mechanical minima by form" on this page.

Which standards cover TC1?

GB/T 3621—2022, GB/T 3623—2022

Where is TC1 typically used?

Airframe & lightweight (Aerospace)

In which forms is TC1 available?

Tube, plate, strip, bar, forgings, wire and other forms — sizes and delivery condition confirmed per order, with EN 10204 3.1 / 3.2 certification.

Same series

Download PDF datasheet

This grade’s datasheet as an A4 PDF — for filing, printing or forwarding to colleagues.

Download PDF datasheet

Supply & enquiry

Tube & pipeφ1 – 219 × 0.25 – 25 mmPlate4.76 – 80 mmBarφ8 – 300 mmWire & filler metalsφ0.01 – 8 mm

For this grade we can supply, against your service conditions:

Or email us: info@kochlin.com