Kochlin SPECIAL ALLOYS · SINCE 2009

UNS R524003.7235 · Ti-0.2Pd

Palladium-bearing, crevice-corrosion resistant — severe chloride media

Titanium
Units
Tensile Rm
345
MPa · ≥ std. min
Yield Rp0.2
275
MPa · ≥ std. min
Elongation A
20
% · ≥ std. min
Service limit
300
°C · indicative max
Density
4.51
g/cm³

Chemical composition

Ti 99%Pd 0.18%Minor & residual 1.2%

Nominal: mid-range where both limits are given, the cap where only a maximum is, balance takes the remainder. Exact specified ranges below.

ElementName Content %
Main elements2 elements
Ti TitaniumBal.
Pd Palladium0.12 – 0.25%
ElementName Content %
Minor & residual7 elements
O Oxygen≤ 0.25%
Fe Iron≤ 0.3%
C Carbon≤ 0.08%
N Nitrogen≤ 0.03%
H Hydrogen≤ 0.015%
Other Other elements, each≤ 0.1%
Other Other elements, total≤ 0.4%

Mechanical minima by form

Guaranteed values differ by form, size and delivery condition; quotations confirm the specification, form, size and condition.

FormCondition Rm MPaRp0.2 MPaA ≥ %Other requirements and notes
Bar and forgings
Bar and billet (≤76 mm thick, cross-section ≤64.5 cm²)Annealed ≥ 345 (50 ksi) ≥ 275 (40 ksi) ≥ 20
ForgingsF-7: Annealed ≥ 345 (50 ksi) ≥ 275 (40 ksi) ≥ 20 Also specified: Reduction of area Z ≥ 30 %
Applies to forgings up to 1935 mm² (3 in.²) in cross section; larger sections by agreement.
ForgingsF-7H: Annealed (H grade, for pressure-vessel use) ≥ 400 (58 ksi) ≥ 275 (40 ksi) ≥ 20 Also specified: Reduction of area Z ≥ 30 %
Applies to forgings up to 1935 mm² (3 in.²) in cross section; larger sections by agreement.
H grades (e.g. F-2H) share the chemistry of the numeric grade with a higher 400 MPa tensile floor, mainly for pressure vessels.
Plate, sheet and strip
Plate, sheet and stripAnnealed ≥ 345 (50 ksi) 275 – 450 ≥ 20

Grade 7 has the same strength as Grade 2 (Rm ≥ 345 MPa) — it is chosen for the crevice-corrosion resistance that palladium gives.

More detail 1

Where higher strength is needed, order Grade 7H (Rm ≥ 400 MPa).

Where this grade is recommended

Matched in 13 service conditions; ranks and scores computed from the condition-scoring matrix.

Service conditionIndustry TemperatureRankScore
Wet Cl₂, chlor-alkali Chemical Processing ≤ 80 °C 3 / 11 94
Flowlines (chlorides) Oil & Gas ≤ 80 °C 1 / 9 92
HCl & reducing acids Chemical Processing ≤ 60 °C 6 / 8 86
Nitric & oxidising media Chemical Processing ≤ 60 °C 7 / 7 46
Evaporators & tube bundles Chemical Processing ≤ 80 °C 8 / 8 45
Seawater piping & HX Marine & Offshore ≤ 40 °C 11 / 11 45
Aquaculture & harbour works Marine & Offshore Seawater ≤ 40 °C 8 / 8 44
Ballast & tank systems Marine & Offshore ≤ 40 °C 10 / 10 44
Desalination & RO Marine & Offshore ≤ 45 °C 12 / 12 44
Organic & acetic acid Chemical Processing 120 – 200 °C 7 / 7 43
Firewater & deluge Marine & Offshore ≤ 40 °C 7 / 7 43
Water & gas injection Oil & Gas ≤ 60 °C 8 / 8 43

Top 12 by score shown; 1 more matched conditions — browse them by industry in the selector. Open the selector →

Designations & equivalents

UNSR52400
W.Nr. (Germany)3.7235
Trade name(s)Ti-0.2Pd
ASTM / AISIB265 / B338 / B348 / B381 / B861 / B862 / B863 (Grade 7)

Cross-references are common near-equivalents for search and shortlisting; substitution across standards requires clause-by-clause verification. All grades in one cross-reference table →

Applicable standards

8 specifications. Name the standard and its edition on the order.

Guaranteed values and required tests differ between specifications — see Mechanical minima by form for the figures per form.

Frequently asked questions

What is TA9 (Ti-0.2Pd / Gr.7)?

TA9 (Ti-0.2Pd / Gr.7) — Titanium. Palladium-bearing, crevice-corrosion resistant — severe chloride media

What is the maximum service temperature of TA9?

Typically about 300 °C; the practical limit depends on media, stress and design life — acceptance per the governing standard.

What is the tensile strength of TA9?

The specified minimum tensile strength is 345 MPa for the main product form. Minima for other forms and sizes are listed under "Mechanical minima by form" on this page.

Which standards cover TA9?

ASTM B265, ASTM B348, ASTM B338, ASTM B381, ASTM B861, ASTM B862, ASTM B863, ASTM B363

Where is TA9 typically used?

Wet Cl₂, chlor-alkali (Chemical Processing); Flowlines (chlorides) (Oil & Gas); HCl & reducing acids (Chemical Processing); Nitric & oxidising media (Chemical Processing)

In which forms is TA9 available?

Tube, plate, strip, bar, forgings, wire and other forms — sizes and delivery condition confirmed per order, with EN 10204 3.1 / 3.2 certification.

Same series

Download PDF datasheet

This grade’s datasheet as an A4 PDF — for filing, printing or forwarding to colleagues.

Download PDF datasheet

Supply & enquiry

Tube & pipeφ1 – 219 × 0.25 – 25 mmPlate4.76 – 80 mmBarφ8 – 300 mmWire & filler metalsφ0.01 – 8 mm

For this grade we can supply, against your service conditions:

Or email us: info@kochlin.com