UNS R504003.7035 · CP Titanium Grade 2 / CP-Ti Grade 2

ГОСТ≈ ВТ1-0

Workhorse CP titanium — mainstay of chemical process equipment

Titanium
Units
Tensile Rm
345
MPa · ≥ std. min
Yield Rp0.2
275
MPa · ≥ std. min
Elongation A
20
% · ≥ std. min
Service limit
300
°C · indicative max
Density
4.51
g/cm³

Chemical composition

Ti 99%Minor & residual 0.68%

Nominal: elements given only as a maximum are counted at the cap; the balance takes the remainder.

ElementName Content %
Main elements1 element
Ti TitaniumBal.
ElementName Content %
Minor & residual5 elements
O Oxygen≤ 0.25%
Fe Iron≤ 0.3%
C Carbon≤ 0.08%
N Nitrogen≤ 0.03%
H Hydrogen≤ 0.015%

Mechanical minima by form

Guaranteed values differ by form, size and delivery condition; quotations confirm the specification, form, size and condition.

FormCondition Rm MPaRp0.2 MPaA ≥ %Other requirements and notes
Bar and forgings
Bar and billetAnnealed, t ≤76 mm and section ≤64.5 cm² ≥ 345 (50 ksi) ≥ 275 (40 ksi) ≥ 20
ForgingsF-2: Annealed ≥ 345 (50 ksi) ≥ 275 (40 ksi) ≥ 20 Also specified: Reduction of area Z ≥ 30 %
Applies to forgings up to 1935 mm² (3 in.²) in cross section; larger sections by agreement.
ForgingsF-2H: Annealed (H grade, for pressure-vessel use) ≥ 400 (58 ksi) ≥ 275 (40 ksi) ≥ 20 Also specified: Reduction of area Z ≥ 30 %
Applies to forgings up to 1935 mm² (3 in.²) in cross section; larger sections by agreement.
H grades (e.g. F-2H) share the chemistry of the numeric grade with a higher 400 MPa tensile floor, mainly for pressure vessels.
Plate, sheet and strip
Plate, sheet and stripAnnealed, t ≤25 mm ≥ 345 (50 ksi) 275 – 450 ≥ 20
Tube and pipe
Seamless pipe and tubeAnnealed ≥ 345 (50 ksi) 275 – 450 ≥ 20

Where this grade is recommended

Matched in 34 service conditions; ranks and scores computed from the condition-scoring matrix.

Service conditionIndustry TemperatureRankScore
Nitric & oxidising media Chemical Processing ≤ 60 °C 1 / 7 92
Specialty gas lines Semiconductor & Vac-Electronics ≤ 120 °C 1 / 4 92
Fuel-cell bipolar plates Automotive & Racing ≤ 90 °C 2 / 4 92
Fuel-cell bipolar plates Hydrogen & New Energy ≤ 90 °C 2 / 4 92
Sterilisation trays Medical Devices In-body (37 °C) 1 / 4 90
Process chambers & liners Semiconductor & Vac-Electronics ≤ 400 °C 1 / 4 90
Evaporators & tube bundles Chemical Processing ≤ 80 °C 2 / 8 90
Water electrolysis Hydrogen & New Energy ≤ 90 °C 2 / 5 90
Brine evaporation (MVR) Environmental & FGD ≤ 100 °C 2 / 6 90
Seawater piping & HX Marine & Offshore ≤ 40 °C 5 / 11 90
Pure steam & sterilisation Pharma & Fine Chemicals 121 – 134 °C 1 / 5 88
Lyophilisation & cryo Pharma & Fine Chemicals −80 ~ 20 °C 1 / 4 88

Top 12 by score shown; 22 more matched conditions — browse them by industry in the selector. Open the selector →

Designations & equivalents

UNSR50400
W.Nr. (Germany)3.7035
Trade name(s)CP-Ti Grade 2
ASTM / AISIB265 / B338 / B348 / B381 / B861 / B862 / B863 (Grade 2)
AMS (SAE aerospace)4902 / 4941 / 4942
GOST (Russia)≈ ВТ1-0

Cross-references are common near-equivalents for search and shortlisting; substitution across standards requires clause-by-clause verification. All grades in one cross-reference table →

Applicable standards

11 specifications. Name the standard and its edition on the order.

Guaranteed values and required tests differ between specifications — see Mechanical minima by form for the figures per form.

Frequently asked questions

What is CP Titanium Grade 2?

CP Titanium Grade 2 — Titanium. Workhorse CP titanium — mainstay of chemical process equipment

What is the maximum service temperature of TA2?

Typically about 300 °C; the practical limit depends on media, stress and design life — acceptance per the governing standard.

What is the tensile strength of TA2?

The specified minimum tensile strength is 345 MPa for the main product form. Minima for other forms and sizes are listed under "Mechanical minima by form" on this page.

Which standards cover TA2?

ASTM B265, ASTM B338, ASTM B348, ASTM B381, ASTM B861, ASTM B862, ASTM B863, AMS 4902, AMS 4941, AMS 4942, ASTM B363

Where is TA2 typically used?

Nitric & oxidising media (Chemical Processing); Specialty gas lines (Semiconductor & Vac-Electronics); Fuel-cell bipolar plates (Automotive & Racing); Fuel-cell bipolar plates (Hydrogen & New Energy)

In which forms is TA2 available?

Tube, plate, strip, bar, forgings, wire and other forms — sizes and delivery condition confirmed per order, with EN 10204 3.1 / 3.2 certification.

Same series

Download PDF datasheet

This grade’s datasheet as an A4 PDF — for filing, printing or forwarding to colleagues.

Download PDF datasheet

Supply & enquiry

Tube & pipeφ1 – 219 × 0.25 – 25 mmPlate4.76 – 80 mmBarφ8 – 300 mmWire & filler metalsφ0.01 – 8 mm

For this grade we can supply, against your service conditions:

Or email us: info@kochlin.com

Further reading: Alloy 625 Grade 1 vs Grade 2: a heat-treatment condition, not a quality level