Kochlin SPECIAL ALLOYS · SINCE 2009

Ti-4Al-1.5Mn

ГОСТ≈ ОТ4

Medium-strength sheet and forgings

Titanium
Units
Tensile Rm
685
MPa · ≥ std. min
Yield Rp0.2
620
MPa · ≥ std. min
Elongation A
25
% · ≥ std. min
Service limit
400
°C · indicative max
Density
4.55
g/cm³

Chemical composition

Ti 94%Al 4.3%Mn 1.4%Minor & residual 0.61%

Nominal: mid-range where both limits are given, the cap where only a maximum is, balance takes the remainder. Exact specified ranges below.

ElementName Content %
Main elements3 elements
Ti TitaniumBal.
Al Aluminium3.5 – 5%
Mn Manganese0.8 – 2%
ElementName Content %
Minor & residual5 elements
Fe Iron≤ 0.3%
O Oxygen≤ 0.15%
C Carbon≤ 0.1%
N Nitrogen≤ 0.05%
H Hydrogen≤ 0.012%

Mechanical minima by form

Guaranteed values differ by form, size and delivery condition; quotations confirm the specification, form, size and condition.

FormCondition Rm MPaRp0.2 MPaA ≥ %
PlateM, t 0.5–1.0 mm (Annealed) 685 – 920 ≥ 620 ≥ 25
PlateM, t >1.0–2.0 mm (Annealed) 685 – 920 ≥ 620 ≥ 15
PlateM, t >2.0–25.0 mm (Annealed) 685 – 920 ≥ 620 ≥ 12

Where this grade is recommended

Matched in 1 service conditions; ranks and scores computed from the condition-scoring matrix.

Service conditionIndustry TemperatureRankScore
Airframe & lightweight Aerospace ≤ 200 °C 9 / 10 78

Designations & equivalents

Trade name(s)Ti-4Al-1.5Mn
GOST (Russia)≈ ОТ4

Cross-references are common near-equivalents for search and shortlisting; substitution across standards requires clause-by-clause verification. All grades in one cross-reference table →

Applicable standards

2 specifications. Name the standard and its edition on the order.

Guaranteed values and required tests differ between specifications — see Mechanical minima by form for the figures per form.

Frequently asked questions

What is TC2 (Ti-4Al-1.5Mn)?

TC2 (Ti-4Al-1.5Mn) — Titanium. Medium-strength sheet and forgings

What is the maximum service temperature of TC2?

Typically about 400 °C; the practical limit depends on media, stress and design life — acceptance per the governing standard.

What is the tensile strength of TC2?

The specified minimum tensile strength is 685 MPa for the main product form. Minima for other forms and sizes are listed under "Mechanical minima by form" on this page.

Which standards cover TC2?

GB/T 3621—2022, GB/T 3623—2022

Where is TC2 typically used?

Airframe & lightweight (Aerospace)

In which forms is TC2 available?

Tube, plate, strip, bar, forgings, wire and other forms — sizes and delivery condition confirmed per order, with EN 10204 3.1 / 3.2 certification.

Same series

Download PDF datasheet

This grade’s datasheet as an A4 PDF — for filing, printing or forwarding to colleagues.

Download PDF datasheet

Supply & enquiry

Tube & pipeφ1 – 219 × 0.25 – 25 mmPlate4.76 – 80 mmBarφ8 – 300 mmWire & filler metalsφ0.01 – 8 mm

For this grade we can supply, against your service conditions:

Or email us: info@kochlin.com